If the E2700 controller has failed, you must replace it. In this case, you cannot perform a controlled shutdown.
Steps
- Put on antistatic protection.
- Label each cable attached to the E2700 controller, so you can reconnect the cables correctly.
- Turn off power to the enclosure, which turns power off to both controllers.
- Wait until all LED and seven-segment display activity on the rear of the controller has stopped.
- Remove the cables.
- Remove the controller, as described in the E2700 controller documentation.
- Insert the new controller, as described in the E2700 controller documentation.
- Replace all cables.