Table of ContentsView in Frames

LEDs on the operator display panel

Each E2800 and E5700 controller shelf or drive shelf has LEDs located on the operator display panel (ODP). The ODP is visible through the front bezel of a controller shelf and through the left end cap of a drive shelf.

The following figure shows the LEDs on the ODP for the E2812, E2824, and E5724 controller shelves:

Note: The above figure also applies to DE212C and DE224C drive shelves.

The following figure shows the LEDs on the ODP for the E2860 and E5760 controller shelf:

1 Power
2 Attention
3 Locate
The following table describes the LEDs on the ODP and their operational states:
LED Status indicator Description
Power Green

One or more power supplies are supplying power to the shelf.

Off

The shelf is not receiving power.

Attention Amber
There is an error with the function of one or more of the following:
  • Shelf
  • Drives
  • IOMs
  • Power supplies
  • Fans
Off

The shelf, drives, IOMs, power supply, and fans are functioning correctly.

Locate Blue

There is an active request to physically locate the shelf.

Note: Locate LEDs turn off automatically after 30 minutes.