Table of ContentsView in Frames

Storage capabilities for all storage systems do not display in the vCenter Server

Issue
Storage capabilities for all storage systems are not visible in the vCenter Server.
Cause
This problem occurs when FAS/V-Series VASA Provider is unable to collect all the data from all registered storage systems within the default time period that is defined in the vasa.properties file.
Corrective action

Modify the time interval used to refresh the data, as follows:

  1. Open the vasa.properties file.
  2. Increase the default value of 120,000 milliseconds.
    Note: You must type a new value without a comma in the vasa.properties file.
  3. Unregister FAS/V-Series VASA Provider from all vCenter Servers to which it is registered.
  4. Restart the FAS/V-Series VASA Provider service.
  5. Wait approximately 15 minutes and then register FAS/V-Series VASA Provider with the vCenter Server.