How to determine the status of a discrete SP sensor

The Status column of the system sensors command output in the SL CLI shows the discrete sensors' conditions in hexadecimal values. To interpret the status values of most discrete sensors, you can use the system sensors get sensor_name command in the SL CLI.

Discrete sensors do not have thresholds. Their readings (displayed under the Current column in the system sensors command output) do not carry actual meanings and thus are ignored by the SP.

Examples of discrete sensors include sensors for the fan, power supply unit (PSU) fault, and system fault. The specific list of discrete sensors depends on the platform.

While the system sensors get sensor_name command displays the status information for most discrete sensors, it does not provide status information for the System_FW_Status, System_Watchdog, PSU1_Input_Type, and PSU2_Input_Type discrete sensors. However, you can use the following information to interpret these sensors' status values.

System_FW_Status

The System_FW_Status sensor's condition appears in the form of 0xAABB. You can combine the information of AA and BB to determine the condition of the sensor.

AA can have one of the following values:
01
System firmware error
02
System firmware hang
04
System firmware progress
BB can have one of the following values:
00     
System software has properly shut down
01
Memory initialization in progress
02
NVMEM initialization in progress (when NVMEM is present)
04
Restoring memory controller hub (MCH) values (when NVMEM is present)
05
User has entered Setup
13
Booting the operating system or LOADER
1F
BIOS is starting up
20
LOADER is running
21
LOADER is programming the primary BIOS firmware. You must not power down the system.
22
LOADER is programming the alternate BIOS firmware. You must not power down the system.
2F
Data ONTAP is running
60
SP has powered off the system
61
SP has powered on the system
62
SP has reset the system
63
SP watchdog power cycle
64
SP watchdog cold reset

For instance, the System_FW_Status sensor status 0x042F means "system firmware progress (04), Data ONTAP is running (2F)."

System_Watchdog

The System_Watchdog sensor can have one of the following conditions:

0x0080
The state of this sensor has not changed
0x0081
Timer interrupt
0x0180
Timer expired
0x0280
Hard reset
0x0480
Power down
0x0880
Power cycle

For instance, the System_Watchdog sensor status 0x0880 means a watchdog timeout occurs and causes a system power cycle.

PSU1_Input_Type and PSU2_Input_Type

For direct current (DC) power supplies, the PSU1_Input_Type and PSU2_Input_Type sensors do not apply. For alternating current (AC) power supplies, the sensors' status can have one of the following values:

0x01xx
220V PSU type
0x02xx
110V PSU type

For instance, the PSU1_Input_Type sensor status 0x0280 means that the sensor reports that the PSU type is 110V.

Examples of the system sensors get sensor_name command output for discrete sensors

The following examples show the results of entering system sensors get sensor_name for the discrete sensors CPU0_Error and IO_Slot1_Present:
SP toaster> system sensors get CPU0_Error
Locating sensor record...
Sensor ID              : CPU0_Error (0x67)
 Entity ID             : 7.97
 Sensor Type (Discrete): Temperature
 States Asserted       : Digital State
                         [State Deasserted]
SP toaster> system sensors get IO_Slot1_Present
Locating sensor record...
Sensor ID              : IO_Slot1_Present (0x74)
 Entity ID             : 11.97
 Sensor Type (Discrete): Add-in Card
 States Asserted       : Availability State
                        [Device Present]