Search within this manual
Search all Support content
Clustered Data ONTAP® 8.2
SAN Configuration Guide
iSCSI configurations
Recommended number of paths to avoid single points of failure
Single-network and multi-network single-node configuration in an iSCSI SAN
Single-network HA pair in an iSCSI SAN
Multi-network HA pair in an iSCSI SAN
Direct-attached single-node configurations in an iSCSI SAN
VLANs for iSCSI configurations
Static VLANs
Dynamic VLANs
Fibre Channel configurations
Recommended number of paths to avoid single points of failure
FC onboard and expansion port combinations
Fibre Channel supported hop counts
Fibre Channel supported speeds
Fibre Channel switch configuration best practices
Host multipathing software requirements
62xx supported fibre channel configurations
62xx target port configuration recommendations
62xx Single-node configurations
62xx: Single-fabric HA configurations
62xx: Multifabric HA configurations
6040 and 6080 supported fibre channel configurations
6040 and 6080 target port configuration recommendations
60xx Single-node configurations
6040 and 6080: Single-fabric HA configurations
6040 and 6080: Multifabric HA pair
32xx supported fibre channel configurations
32xx target port configuration recommendations
32xx Single-node configurations
32xx: Single-fabric HA configurations
32xx: Multifabric HA configurations
31xx supported fibre channel configurations
31xx target port configuration recommendations
31xx Single-node configurations
31xx : Single-fabric HA pair
31xx : Multifabric HA pair
FAS2240 Supported configurations
FAS2240 Single-fabric Single-node configurations
FAS2240 Multifabric single-node configurations
Fibre Channel over Ethernet overview
Recommended number of paths to avoid single points of failure
FCoE initiator and target combinations
Fibre Channel over Ethernet supported hop count
Fibre Channel over Ethernet supported configurations
FCoE initiator to FC target configuration
FCoE end-to-end configuration
FCoE mixed with FC
FCoE mixed with IP storage protocols
Fibre Channel and FCoE zoning
World Wide Name-based zoning
Individual zones
Single-fabric zoning
Dual-fabric HA pair zoning
FC and FCoE LIFs on the same port need to be in separate zones
Shared SAN configurations
ALUA Configurations
Configuration limits for FC, FCoE, and iSCSI configurations
SAN configurations always use FlexVol volumes
Supported number of nodes for SAN configurations
SAN Configuration limit parameters and definitions
Host operating system limits for SAN configurations
SAN configuration limits
SAN configuration limits specifically for the FAS2220
FC switch configuration limits
Calculating queue depth
Setting queue depths on AIX hosts
Setting queue depths on HP-UX hosts
Setting queue depths on Solaris hosts
Setting queue depths on VMware hosts
Setting queue depths on Windows hosts
Copyright information
Trademark information
How to send your comments