Table of ContentsView in Frames

Verifying path failover for array LUNs in a stand-alone system

It is important to demonstrate that a stand-alone V-Series system continues to operate on a single path.

Steps

  1. Set your privilege level to advanced: priv set advanced
  2. Set port 0a offline by using the following command:fcadmin offline 0a
  3. Show the number of disks seen on each adapter using the following command: sysconfig
    No disks will be assigned to adapter 0a.
  4. Show the primary and secondary paths by using the following command: storage show disk -p
  5. Return port 0a to online: fcadmin online 0a