Table of ContentsView in Frames

Displaying brief target adapter information

You can use the fcp config command to display information about target adapters in the system, as well as to quickly detect whether the adapters are active and online.

About this task

The output of the fcp config command depends on the storage system model.

Step

  1. Enter the following command:
    fcp config

    Example

    The fcp config command displays the following output:

    7a:   ONLINE [ADAPTER UP]  PTP  Fabric
            host address 170900
            portname 50:0a:09:83:86:87:a5:09  
            nodename 50:0a:09:80:86:87:a5:09
            mediatype ptp  partner adapter 7a
    
    7b:   ONLINE [ADAPTER UP]  PTP  Fabric
            host address 171800
            portname 50:0a:09:8c:86:57:11:22  
            nodename 50:0a:09:80:86:57:11:22
            mediatype ptp  partner adapter 7b

    Example

    The following example shows output for the 30xx. The fcp config command displays information about the onboard ports connected to the SAN:

    0c:   ONLINE [ADAPTER UP]  PTP  Fabric
            host address 010900
            portname 50:0a:09:81:86:f7:a8:42  
            nodename 50:0a:09:80:86:f7:a8:42
            mediatype ptp  partner adapter 0d
    
    0d:   ONLINE [ADAPTER UP]  PTP  Fabric
            host address 010800
            portname 50:0a:09:8a:86:47:a8:32  
            nodename 50:0a:09:80:86:47:a8:32
            mediatype ptp  partner adapter 0c