Verifying that DCB is configured correctly

If you are using FCoE, you must verify that DCB bridging is configured correctly and that the target adapter has successfully logged into the fabric.

About this task

If FCoE is not configured, you need to consult the switch documentation.
Note: These settings are configured at the switch level, and the storage system discovers and displays these pre-configured settings.

Step

  1. Use the dcb show command to display the DCB settings for each node in the cluster.
    Example
    run -node node1 -command dcb show
    Interface  PGID  Priority           Application             Bandwidth
    ---------  ----  ----------         ------------         ------------
    e3a                                                                  
               0     0 1 2 4 5 6 7      unassigned                   50% 
               1     3                  FCoE                         50% 
    e3b                                                                  
               0     0 1 2 3 4 5 6 7    unassigned                    0% 
    e4a                                                                  
               0     0 1 2 4 5 6 7      unassigned                   50% 
               1     3                  FCoE                         50% 
    e4b                                                                  
               0     0 1 2 3 4 5 6 7    unassigned                    0%