Table of ContentsView in Frames

Viewing plexes and spare pools

You can view the plexes and spare disks or array LUNs. It is useful to view the assignments when you are adding disks or array LUNs to an aggregate, or when you need to identify the pool used by each plex.

Step

  1. Enter one of the following commands.
    sysconfig -r

    or

    aggr status -r

    or

    vol status -r
    Example
    In this example, the aggr status -r command is used to view the disks in plexes and spare disks in disk pools.
    system1> aggr status -r
    
    Aggregate vol0 (online, raid4) (block checksums)
    Plex /vol0/plex0 (online, normal, active, pool1)
    RAID group /vol0/plex0/rg0 (normal)
    
    RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    --------- ------  ------------- ---- ---- ---- ----- --------------    ---
    parity    9a.16   9a    1   0   FC:A   1  FCAL 10000 34000/69632000    34
    data      9a.17   9a    1   1   FC:A   1  FCAL 10000 600/1228800       76
    data      9a.20   9a    1   4   FC:A   1  FCAL 10000 34000/69632000    34
    
    Aggregate GreG (online, raid4) (block checksums)
    Plex /GreG/plex0 (online, normal, active, pool1)
    RAID group /GreG/plex0/rg0 (normal)
    
    RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    --------- ------  ------------- ---- ---- ---- ----- --------------    ---
    parity    9a.18   9a    1   2   FC:A   1  FCAL 10000 34000/69632000    34
    data      9a.19   9a    1   3   FC:A   1  FCAL 10000 34000/69632000    34
    
    
    Pool1 spare disks
    
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    Spare disks for block or zoned checksum traditional volumes or aggregates
    spare           9a.24   9a    1   8   FC:A   1  FCAL 10000 34000/69632000    34
    spare           9a.29   9a    1   13  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool0 spare disks (empty)
    
    Partner disks
    
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    partner         9b.25   9b    1   9   FC:B   1  FCAL 10000 0/0               34
    partner         9b.16   9b    1   0   FC:B   1  FCAL 10000 0/0               34
    partner         9b.17   9b    1   1   FC:B   1  FCAL 10000 0/0               34
    partner         9b.21   9b    1   5   FC:B   1  FCAL 10000 0/0               34
    partner         9b.18   9b    1   2   FC:B   1  FCAL 10000 0/0               34
    partner         9b.22   9b    1   6   FC:B   1  FCAL 10000 0/0               34
    
    tpubs-cf1>
    Example
    In this example, the vol status -r command is used to view the disks in plexes and spare disks in disk pool.
    system1> vol status -r
    
    Volume vol0 (online, raid4) (block checksums)
      Plex /vol0/plex0 (online, normal, active, pool1)
        RAID group /vol0/plex0/rg0 (normal)
    
          RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
          --------- ------  ------------- ---- ---- ---- ----- --------------    ---
          parity    9a.16   9a    1   0   FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.17   9a    1   1   FC:A   1  FCAL 10000 600/1228800       76
          data      9a.20   9a    1   4   FC:A   1  FCAL 10000 34000/69632000    34
    
    Aggregate aggrz (online, raid4) (block checksums)
      Plex /aggrz/plex0 (online, normal, active, pool1)
        RAID group /aggrz/plex0/rg0 (normal)
    
          RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
          --------- ------  ------------- ---- ---- ---- ----- --------------    ---
          parity    9a.25   9a    1   9   FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.26   9a    1   10  FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.27   9a    1   11  FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.28   9a    1   12  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool1 spare disks
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    Spare disks for block or zoned checksum traditional volumes or aggregates
    spare           9a.24   9a    1   8   FC:A   1  FCAL 10000 34000/69632000    34
    spare           9a.29   9a    1   13  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool0 spare disks (empty)
    
    Partner disks
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    partner         9b.25   9b    1   9   FC:B   1  FCAL 10000 0/0               34
    partner         9b.16   9b    1   0   FC:B   1  FCAL 10000 0/0               34
    partner         9b.17   9b    1   1   FC:B   1  FCAL 10000 0/0               34
    partner         9b.21   9b    1   5   FC:B   1  FCAL 10000 0/0               34
    partner         9b.18   9b    1   2   FC:B   1  FCAL 10000 0/0               34
    partner         9b.22   9b    1   6   FC:B   1  FCAL 10000 0/0               34
    partner         9b.23   9b    1   7   FC:B   1  FCAL 10000 0/0               34