Table of ContentsView in Frames

Aggregate rules when the storage arrays are from the same family

Specific rules apply to how you can lay out array LUNs in aggregates when the storage arrays are from the same storage array vendor and model family.

If your storage arrays are from the same vendor, the rules for adding array LUNs to aggregates are as follows:

The following examples show some options for laying out array LUNs in aggregates when the storage arrays behind a Data ONTAP system are in the same vendor family.

Note: For simplicity, the illustrations show only two storage arrays; your deployment can include more storage arrays.

Example 1: Add LUNs from all storage arrays to a single aggregate

As shown in the following illustration, you can create one aggregate, then add all LUNs from all the storage arrays in the same family to the same aggregate:

This graphic is described by the surrounding text.

Example 2: Distribute and mix LUNs from the storage arrays over multiple aggregates

As shown in the following illustration, you can create multiple aggregates, then distribute and mix the array LUNs from the different storage arrays in the same family over the aggregates:

Note: This example is not supported if you have storage arrays of the same model and one has Fibre Channel drives and the other storage array has SATA drives. In that case, those storage arrays are not considered to be in the same family.