Table of ContentsView in Frames

Discrepancy in the error code message

If you execute the snapdrive storage delete command when both the FC and iSCSI services are up or when they are down, SnapDrive for UNIX displays a wrong error message. The following table gives more details.

Transport protocol

Message displayed (The incorrect message)

Message that should be displayed instead (The correct message)

FCP and iSCSI both are configured

0002-181 Command error: Could not select appropriate File System. Please check the value of fstype in config file, and ensure proper file system is configured in the system.

0002-143 Admin error: Coexistence of linuxiscsi linuxfcp drivers is not supported.

Please ensure only one of the drivers is loaded in the host and retry.

FCP and iSCSI both are not configured

0001-465 Command error: The following filespecs do not exist and cannot be deleted.

0001-877 Admin error: HBA assistant not found. Commands involving LUNs should fail.