Switch zoning for a MetroCluster configuration with array LUNs

Switch zoning defines paths between connected nodes. Configuring the zoning enables you to define which array LUNs can be viewed by a specific Data ONTAP system.

When using switch zoning for a MetroCluster configuration with array LUNs, you must ensure that it meets these requirements:

You can use the following example as a reference when determining zoning for a MetroCluster configuration with array LUNs. The example shows single-initiator zoning for a MetroCluster configuration. The lines in the following example represent zones rather than connections; each line is labeled with its zone number:

This graphic depicts the switch zones in an example MetroCluster configuration with array LUNs. The graphic is described by the surrounding text.
In the example illustration, array LUNs are allocated on each storage array for the MetroCluster configuration. LUNs of equal size are provisioned on the storage arrays at both sites, which is a SyncMirror requirement. Each Data ONTAP system has two paths to array LUNs. The ports on the storage array are redundant, and are configured as follows:

The redundant port pairs on each storage array form alternate paths. Therefore, both the ports of the port pairs can access the LUNs on the respective storage arrays.

The following table shows the zones for this example:
Zone Data ONTAP controller and FC initiator port Storage array port
Switch A1
z1 Controller A1: Port 0a Port 1A
z2 Controller A1: Port 0b Port 2A'
z3 Controller A1: Port 0c Port 1A'
z4 Controller A1: Port 0d Port 2A
Switch A2
z5 Controller A2: Port 0a Port 1B
z6 Controller A2: Port 0b Port 2B'
z7 Controller A2: Port 0c Port 1B'
z8 Controller A2: Port 0d Port 2B
Switch B1  
z9 Controller A3: Port 0a Port 1C'
z10 Controller A3: Port 0b Port 2C
z11 Controller A3: Port 0c Port 1C
z12 Controller A3: Port 0d Port 2C'
Switch B2  
z13 Controller A4: Port 0a Port 1D'
z14 Controller A4: Port 0b Port 2D
z15 Controller A4: Port 0c Port 1D
z16 Controller A4: Port 0d Port 2D'
The following table shows the zones for the FC-VI connections at Site A and Site B:
Zone Data ONTAP controller and FC initiator port Switch
Site A  
zX Controller A1: Port FC-VI a Switch A1
zY Controller A1: Port FC-VI b Switch A2
zX Controller A2: Port FC-VI a Switch A1
zY Controller A2: Port FC-VI b Switch A2
Site B  
zX Controller B1: Port FC-VI a Switch B1
zY Controller B1: Port FC-VI b Switch B2
zX Controller B2: Port FC-VI a Switch B1
zY Controller B2: Port FC-VI b Switch B2