Table of ContentsView in Frames

Confirming that the DR partners have come online

After the switchover is complete, you should verify that the DR partners have taken ownership of the disks and the partner SVMs have come online.

Steps

  1. Confirm that the aggregate disks have switched over to the disaster site: storage disk show -fields owner,dr-home
    Example
    In this example, the output shows that the switched over disks have the dr-home field set:
    mcc1A::> storage disk show -fields owner,dr-home
    disk                              owner   dr-home                     
    --------------------------------- ------- ------- 
    mcc1-a1:mcc-sw1A-fab1:1-7.126L1   mcc1-a1 -       
    mcc1-a1:mcc-sw1A-fab1:1-7.126L24  mcc1-a1 mcc1-b2 
    mcc1-a1:mcc-sw1A-fab1:1-7.126L36  mcc1-a1 mcc1-b2 
    mcc1-a1:mcc-sw1A-fab1:1-7.126L38  mcc1-a1 -       
    ....
    mcc1-a1:mcc-sw1A-fab1:1-7.126L48  mcc1-a1 -       
    mcc1-a1:mcc-sw1A-fab1:1-7.126L49  mcc1-a1 -       
    mcc1-a1:mcc-sw1A-fab1:1-8.126L6   mcc1-a1 -       
    mcc1-a1:mcc-sw1A-fab1:1-8.126L13  mcc1-a1 mcc1-b2 
    mcc1-a1:mcc-sw1A-fab1:1-8.126L23  mcc1-a1 mcc1-b2 
    mcc1-a1:mcc-sw1A-fab1:1-8.126L24  mcc1-a1 mcc1-b2 
    
  2. Check that the aggregates were switched over by using the storage aggregate show command.
    Example
    In this example, the aggregates were switched over. The root aggregate (aggr0_b2) is in a degraded state. The data aggregate (b2_aggr2) is in a mirrored, normal state:
    mcc1A::*> storage aggregate show
    
    .
    .
    .
    mcc1-b Switched Over Aggregates:
    Aggregate     Size Available Used% State   #Vols  Nodes            RAID Status
    --------- -------- --------- ----- ------- ------ ---------------- ------------
    aggr0_b2    227.1GB   45.1GB    80% online       0 mcc1-a1          raid_dp,
                                                                       mirror
                                                                       degraded
    b2_aggr1    227.1GB   200.3GB    20% online       0 mcc1-a1          raid_dp,
                                                                       mirrored
                                                                       normal
    
  3. Confirm that the secondary SVMs have come online by using the vserver show command.
    Example
    In this example, the previously dormant sync-destination SVMs on the secondary site have been activated and have an Admin State of running:
    mcc1A::*> vserver show
                                            Admin      Root                 Name    Name
    Vserver         Type  Subtype           State      Volume    Aggregate  Service Mapping
    -----------     ----- ----------        ---------- --------- ---------- ------- -------
    ...
    mcc1B-vs1b-mc  data   sync-destination  running    vs1b_vol   aggr_b1   file    file