After the switchover is complete, you should verify that the DR partners have taken ownership of the disks and the partner SVMs have come online.
mcc1A::> storage disk show -fields owner,dr-home disk owner dr-home --------------------------------- ------- ------- mcc1-a1:mcc-sw1A-fab1:1-7.126L1 mcc1-a1 - mcc1-a1:mcc-sw1A-fab1:1-7.126L24 mcc1-a1 mcc1-b2 mcc1-a1:mcc-sw1A-fab1:1-7.126L36 mcc1-a1 mcc1-b2 mcc1-a1:mcc-sw1A-fab1:1-7.126L38 mcc1-a1 - .... mcc1-a1:mcc-sw1A-fab1:1-7.126L48 mcc1-a1 - mcc1-a1:mcc-sw1A-fab1:1-7.126L49 mcc1-a1 - mcc1-a1:mcc-sw1A-fab1:1-8.126L6 mcc1-a1 - mcc1-a1:mcc-sw1A-fab1:1-8.126L13 mcc1-a1 mcc1-b2 mcc1-a1:mcc-sw1A-fab1:1-8.126L23 mcc1-a1 mcc1-b2 mcc1-a1:mcc-sw1A-fab1:1-8.126L24 mcc1-a1 mcc1-b2
mcc1A::*> storage aggregate show . . . mcc1-b Switched Over Aggregates: Aggregate Size Available Used% State #Vols Nodes RAID Status --------- -------- --------- ----- ------- ------ ---------------- ------------ aggr0_b2 227.1GB 45.1GB 80% online 0 mcc1-a1 raid_dp, mirror degraded b2_aggr1 227.1GB 200.3GB 20% online 0 mcc1-a1 raid_dp, mirrored normal
mcc1A::*> vserver show Admin Root Name Name Vserver Type Subtype State Volume Aggregate Service Mapping ----------- ----- ---------- ---------- --------- ---------- ------- ------- ... mcc1B-vs1b-mc data sync-destination running vs1b_vol aggr_b1 file file